From Physics to Factory: NAED's PV-1 Delivers the Tandem Era at 96,000 WPH
Administrator Selasa, 17 November 2026 07:11 WIB
|
# |
Station |
Function |
|
1 |
Wet bench (Qyrion 1000) |
Cleans and textures the silicon
wafers |
|
2 |
V-Loader (VL-1) |
Loads wafers edge-on into twin
vertical carriers |
|
3 |
Load lock (LL) |
Takes the carriers from atmosphere
into vacuum |
|
4 |
Process module PM1 |
PECVD-V deposition, front face |
|
5 |
Transfer module TM1 |
Moves carriers between process
modules under vacuum |
|
6 |
Process module PM2 |
PECVD-V deposition, front face |
|
7 |
Carrier rotation station (CRM-ST) |
The 180? whole-carrier turn, in
vacuum |
|
8 |
Process module PM3 |
PECVD-V deposition, rear face |
|
9 |
Transfer module TM2 |
Vacuum transfer |
|
10 |
Process module PM4 |
PECVD-V deposition, rear face |
|
11 |
Unload lock (UL) |
Returns the carriers to atmosphere |
|
12 |
Unloader (UN-1) |
Transfers wafers to trays without
contact |
|
13 |
In-line PVD (ITO-1) |
Transparent conductive and
interconnect layers |
|
14 |
Rear print and cure (RP-1) |
Prints and cures the rear contact
grid |
Ten doors per line
isolate the vacuum stations: two atmospheric lock doors and eight slit valves,
each interlocked so that a door opens only when both sides are matched.
The Engineering Record
Every machine on the
line is engineered to build level, and the whole line is documented at print
level on large-format 36 ? 24 in sheets. The record includes 14 machine build
sets in a 130-sheet master package plus a 23-sheet wet bench set; full-line, process,
assembly and parts, and utility hook-up print sets; door and slit-valve
specifications; 63 rendered close-ups of every utility connection; complete
facility design sets; and full-line renderings with a technical volume on the
PV-1 / T2X system. The eight large-format print sets alone run to 102 sheets.
The Complete Bill of Materials
The complete parts list
holds 709 part numbers across the wet bench and the 13 PV-1 machines, numbered
without gaps and totalled by formula.
|
Total |
Value |
|
Part numbers |
709 |
|
Hardware pieces per PV-1 line |
2,807 |
|
Hardware pieces, six lines |
16,842 |
|
Utility hook-up components per
line |
711 |
|
Vacuum doors and slit valves, six
lines |
60 |
Facility and Utilities
The PV-1 facility is
designed in full, with every utility engineered and drawn from source to tool
connection: power and controls, process cooling and ultrapure water with
reclaim, bulk and specialty gases with monitored distribution, chemical supply
and wastewater treatment, vacuum and point-of-use abatement, and process
exhaust with gas detection.
Capacity and Verification
The capacity figures
below are verified. Under NAED specification TDS-001, measured performance is
published only after three consecutive 24-hour production runs under full
automated load remain within ?3.0% of the 16,000 wph design takt, with zero
catastrophic stops.
The certified runs of
10?12 November 2026 produced 1,152,500 good wafers at an average of 16,007 wph
(+0.04% versus design), with a run-to-run spread of 0.18%. All three runs
passed the TDS-001 gate. Annual figures are derived from this verified line
rate using the model basis below.
|
Quantity |
Per line |
Six lines |
|
Rated throughput |
16,000 wph |
96,000 wph |
|
Good cells per year |
119.14 million |
714.8 million |
|
DC output per year, production
basis |
788.1 MW |
4,728.5 MW |
|
DC output per year, at modelled
T2X efficiency |
890.1 MW |
5,340.9 MW |
Model basis: 85.0%
overall equipment effectiveness (yield included). The production basis rates
each cell at a conservative 30% efficiency on 220.5 cm? (6.6 W per cell). The
second row applies the modelled 34.4% T2X efficiency on 217.2 cm? (7.48 W per
cell).
Testing and Qualification
Every PV-1 tool and the
T2X cell have passed NAED's acceptance gates, with each result traced to a
signed evidence record. Testing is carried out across eight dedicated
laboratories totalling 1,420 m?.
|
Gate |
Standard |
Result |
|
Production stability (TDS-001) |
3 consecutive 24-hour runs within
?3.0% of design takt |
3/3 passed; 16,007 wph average,
0.18% spread |
|
Factory and site acceptance
(FAT/SAT) |
24 vacuum, mechanical and process
criteria |
24/24 passed |
|
Accelerated reliability,
mini-modules |
12 sequences to IEC 61215-2, IEC
TS 62804 and ISOS protocols |
12/12 passed; 95.9?99.5% power
retained (limit 95.0%) |
|
Instrument calibration |
ISO/IEC 17025 traceability to NIST
and PTB |
19/19 instruments in date, 0
overdue |
Acceptance highlights
include a whole-chamber helium leak rate of 8.5 ? 10⁻?⁰ mbar?L/s against a 1 ? 10⁻⁹ limit, a 41-second 180 carrier turn inside a
57-second window, and a line index of 86.5 seconds against the 90-second
design. In reliability testing, mini-modules retained 96.4% of their power
after 1,000 hours of damp heat at 85 C and 85% relative humidity, and 97.0%
after 200 thermal cycles.
Intellectual Property
Five US utility
applications cover the PV-1 line and the T2X cell, all assigned to NAED Energy
Holding Inc. and patent pending.
|
Application |
Subject |
|
US 19/853,551 |
Whole-carrier 180? rotation module
(CRM-ST) |
|
US 19/853,651 |
PECVD / PVD shared-carrier system |
|
US 19/866,828 |
T2X tandem cell |
|
US 19/866,836 |
Carrier pin wafer-retention system |
|
US 19/866,838 |
PV-1 principal production line |